DELSTAR CONVERTER MODULE
(AUTO STAR DELTA STAR CONVERTER)
FOR USE WITH EXISTING STAR DELTA STARTER

SYNOPSIS:

Delstar Converter Module is an electronic system to be interfaced with the existing Star Delta starter. When the load on the motor is less than 50% of full load, it switches the motor to operate in STAR to SAVE ENERGY. When the load increases beyond 50%, it automatically switches the motor to operate in DELTA. The starting regimen is not disturbed.

This module is recommended for applications where load changes are not too fast. Suitable for any capacity motor by using appropriate Current Transformer(C.T)and calibrating the same for the appropriate capacity of the Motor(carried out at the Factory before despatch).

DELSTAR CONVERTER MODULE - MODEL SM 2D
DELSTAR CONVERTER MODULE - MODEL EM1
MODEL SM 2D MODEL EM1



DELSTAR CONVERTER MODULE - MODEL EM1P



DELSTAR CONVERTER MODULE - MODEL EM2

MODEL EM1P

MODEL EM2

                                                                                                                                          TOP

ADVANTAGES

  • Energy saving(Refer to the Energy Saving Data in chart below)
  • Reduction in KVA , contributing to reduction in maximum demand.
  • Improvement in power factor
  • Motor runs cooler leading to increased motor life.
  • Motor protection (Run Over Load, Start Over Load, Single Phasing and Motor Over Temperature Trips).

    TOP

    SCOPE FOR SAVING

    Given below is a table showing the scope for saving energy for the motors of different capacity ranges at different loads. The actual values will vary from motor to motor and the savings can be higher or lower depending upon electrical parameters and mechanical condition of the motor.

    SAVINGS %
    LOAD % -----------------------------------------------
                        1 TO 15 HP       16 TO 40 HP       41 TO 150 HP

    NO LOAD          76%                 60%                 45%
    10%                 40%                 30%                 22%
    20%                 26%                 22%                 20%
    30%                 15%                 13%                 12%
    40%                   9%                  8%                   7%
    50%                   6%                  5%                   4%

    TOP

    ENERGY SAVING DATA FOR A 5 HP MOTOR

    In tests conducted on a 5 HP motor with a full load current of 7.9 amps the savings on no load is 65.3%, reduction in operating current is upto 79.4%, reduction in demand 78.8% and improvement in power factor 60%. Please refer to the table given below :

    CURRENT
    POWER FACTOR
    POWER
    VOLT AMPS

    Delta

    Star

    Delta

    Star

    Delta

    Star

    Delta

    Star
    3.66
    0.84
    0.17
    0.23
    367.3
    128.6
    2140
    532
    4.61
    0.95
    0.15
    0.24
    476
    165
    3025
    641
    4.68
    0.99
    0.15
    0.34
    545
    233
    3177
    673
    4.74
    1.39
    0.28
    0.65
    866
    606
    2961
    887
    5.04
    2.00
    0.43
    0.80
    1240
    986
    2922
    1231
     5.52
    2.72
    0.53
    0.85
    1741
    1493
    3298
    1735
    6.24
    4.96
    0.71
    0.86
    2691
    2559
    3661
    2918

    Similarly the saving on a 12.5 H.P. motor on no Load is 540 Watts AS AGAINST 740 Watts(73% savings).

    DIFFERENT OPTIONS AVAILABLE ARE

    a) Start in star and changeover to Delta and then operate in Star or delta, based on load.

    b) Start in Delta and changeover to star when the load is less than 50% (for motors with       high starting torque requirement).

    c) Changeover from Star to Delta based on current instead of time.(It is likely that the Motor is started with different loads at different times and the timing set in the timer may not be always suitable for these differing loads. It may be too high or too small. Hence this facility will take care of this type of problem).

    Supply Voltage Required: 230 V or 415 V 50 Hz.

    UNITERRUPTED AND HIGHLY SATISFACTORY FUNCTIONING GUARANTEED.

    TATA ENERGY RESEARCH INSTITUTE, BANGALORE has evaluated the product under actual working conditions and have certified the product. Being recommended by Energy Cell of CONFEDERATION OF INDIAN INDUSTRIES and a number of Energy consultants and Energy Auditors.

    TOP

    Different Models are available - Features\Facilities are given below

    S.NO

    DESCRIPTION

    SM 2

    EM1/EM1P

    EM2/EM2P

    1

    NUMBER OF C.T.s

    3

    1

    1

    2

    ENERGY SAVING

    3

    CURRENT BASED SINGLE PHASING TRIP

    -

    -

    4

    RUN OVERLOAD TRIP

    -

    5

    START OVERLOAD TRIP

    OPTIONAL

    OPTIONAL

    -

    6

    CURRENT INDICATION-LCD FOR OPERATING CURRENT

    OPTIONAL

    OPTIONAL

    OPTIONAL

    7

    HOUR COUNTER

    OPTIONAL

    OPTIONAL

    -

    8

    BY PASS FACILITY

    9

    ENCLOSURE

    M.S POWDER COATED

    M.S.POWDER COATED

    M.S.POWDER COATED

    10

    SIZE IN MM

    240*210*110

    240*210*110

    175*110*75

    NOTES : SM2D and EM1D are same as SM2 and EM1 but provided with Digital Indication for Operating Current, respectively. Similarly, suffix T indicates that the unit is provided with an Hour Counter to log the number of hours of operation in either in Star or Delta. EM1P and EM2P are sealed models corresponding to the respective models with specifications which are identical. However all optional features cannot be provided. The size of EM1P is 125*80*60 mm and EM2P is 100*80*50 mm. These are suitable for use in various areas where there is constraint in space, highly corrosive and explosion prone areas.

    All models are provided with LED Indications for Power On, Star(energy saving), Delta, and all protections. Contactor life can be extended by an addition accessory supplied as optional.

    TOP

    APPLICATION INDUSTRIES

     ;

    TYPICAL APPLICATIONS

    All types of industries including Cement / Sugar / Rubber / Paper / Plastic / Chemical / Petro-Chemical / Fertiliser / Breweries / Distilleries / General / Engineering / Automobile / Tea / Textile / Hotels etc. THE LIST IS ENDLESS.

     ;

    Stirrers/Blenders, Centrifuges, Crushers, Blowers, Chest Agitators, Conveyors, Air Compressors, Machine tools like Wheel lathes, Turret lathes, lathes, Grinders, Planing Machines, Presses, Injection Moulding Machines, Textile Machinery like Two-in-one Twisters, Ring Frames, Carding Machines, Humidification plant motors etc.  ;  ;  ;  ; ;  ;  ;  ;

    TOP

    TYPICAL CASES OF ENERGY BEING SAVED BY some of the PRESENT USERS
    (Savings due to reduction in M.D. and improvement in p.f. which are substantial have not been taken into account). Basis : 2 Shifts and 300 Working Days(5000 Hours) and Rs. 5 /- per KWH.

    CAPACITY OF MOTOR IN H.P. EQUIPMENT OPERATING CURRENT/(POWER CONSUMPTION IN K.W.)
    SAVINGS IN
    KWH/HR
    (UNITS/HR.)
    SAVINGS/
    YEAR IN RUPEES
    PAYBACK
    PERIOD
    APPROX.
    (MONTHS)
    DELTA STAR
    25 Blending M/c 14.2
    (2.6)
    3.8
    (1.7)
    0.9 22500/- 6.4
    25 120T Press 11.7
    (4.48)
    4.6
    (2.11)
    2.27 56250/- 2.4
    30 Two for One Twister 23
    (12.15)
    20
    (11.5)
    0.65 16250/- 8.8
    12.5 Blower 11.8
    (5.04)
    7.7
    (3.44)
    1.60 40000/- 4
    10 Brake fatigue Rig 7.75
    (2.22)
    3.25
    (1.90)
    0.32 8000/- 13.6
    40 Wire drawing machine 25
    (9.5)
    15
    (7.90)
    1.60 40000/- 3.6
    40 Air compressor 16.8/34 6.2/34 1.80 33750/- 4.2

    NOTES

    1) In all cases, we have considered working hours / year as 5000 and rate of energy @ Rs.     5/- per unit.
    2) Savings arising out of reduction in KVA(Maximum Demand), which is substantial, has not     been taken into account for pay-back calculations.  ;

    MORE THAN 650 UNITS ARE WORKING IN SEVERAL INDUSTRIAL ESTABLISHMENTS VERY SATISFACTORILY.